smartctl 6.3 2014-07-26 r3976 [x86_64-linux-3.14.48-std454-amd64] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.12 Device Model: ST31000528AS Serial Number: 9VP83K26 LU WWN Device Id: 5 000c50 026479429 Firmware Version: HP35 User Capacity: 1,000,204,886,016 bytes [1.00 TB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 2.6, 3.0 Gb/s Local Time is: Sat Jan 30 23:10:45 2016 UTC ==> WARNING: A firmware update for this drive may be available, see the following Seagate web pages: http://knowledge.seagate.com/articles/en_US/FAQ/207931en http://knowledge.seagate.com/articles/en_US/FAQ/213891en SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 600) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 172) minutes. SCT capabilities: (0x103b) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 114 099 006 Pre-fail Always - 76004013 3 Spin_Up_Time 0x0023 095 095 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 180 5 Reallocated_Sector_Ct 0x0033 058 058 036 Pre-fail Always - 1740 7 Seek_Error_Rate 0x002f 078 060 030 Pre-fail Always - 78413384 9 Power_On_Hours 0x0032 046 046 000 Old_age Always - 48078 10 Spin_Retry_Count 0x0033 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 90 180 Unknown_HDD_Attribute 0x002b 100 100 000 Pre-fail Always - 0 183 Runtime_Bad_Block 0x0032 097 097 000 Old_age Always - 3 184 End-to-End_Error 0x0033 100 100 097 Pre-fail Always - 0 187 Reported_Uncorrect 0x0032 065 065 000 Old_age Always - 35 188 Command_Timeout 0x0032 093 093 000 Old_age Always - 98785886255 189 High_Fly_Writes 0x003a 098 098 000 Old_age Always - 2 190 Airflow_Temperature_Cel 0x0022 065 063 045 Old_age Always - 35 (Min/Max 33/35) 194 Temperature_Celsius 0x0022 035 040 000 Old_age Always - 35 (0 22 0 0 0) 195 Hardware_ECC_Recovered 0x003a 021 013 000 Old_age Always - 76004013 196 Reallocated_Event_Count 0x0032 058 058 036 Old_age Always - 1740 197 Current_Pending_Sector 0x0032 097 097 000 Old_age Always - 136 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 24 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 ATA Error Count: 109 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 109 occurred at disk power-on lifetime: 46327 hours (1930 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 10 78 8b 72 47 00 1d+09:28:48.364 READ FPDMA QUEUED 60 00 20 40 8b 72 47 00 1d+09:28:48.364 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 1d+09:28:48.363 READ FPDMA QUEUED 60 00 20 ff ff ff 4f 00 1d+09:28:48.363 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 1d+09:28:48.362 READ FPDMA QUEUED Error 108 occurred at disk power-on lifetime: 46327 hours (1930 days + 7 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 08 ff ff ff 4f 00 1d+09:28:45.262 READ FPDMA QUEUED 60 00 20 ff ff ff 4f 00 1d+09:28:45.248 READ FPDMA QUEUED 60 00 10 ff ff ff 4f 00 1d+09:28:45.241 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 1d+09:28:45.212 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 1d+09:28:45.212 READ FPDMA QUEUED Error 107 occurred at disk power-on lifetime: 45931 hours (1913 days + 19 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 08 ff ff ff 4f 00 34d+14:47:13.642 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 34d+14:47:13.642 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 34d+14:47:13.642 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 34d+14:47:13.642 READ FPDMA QUEUED 60 00 08 ff ff ff 4f 00 34d+14:47:13.642 READ FPDMA QUEUED Error 106 occurred at disk power-on lifetime: 45101 hours (1879 days + 5 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 8e 12 80 04 Error: UNC at LBA = 0x0480128e = 75502222 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 08 88 12 80 44 00 00:01:52.188 READ FPDMA QUEUED ec 00 00 00 00 00 a0 00 00:01:52.178 IDENTIFY DEVICE ef 03 45 00 00 00 a0 00 00:01:52.178 SET FEATURES [Set transfer mode] ec 00 00 00 00 00 a0 00 00:01:52.157 IDENTIFY DEVICE 2f 00 01 10 00 00 a0 00 00:01:52.093 READ LOG EXT Error 105 occurred at disk power-on lifetime: 45101 hours (1879 days + 5 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 8e 12 80 04 Error: UNC at LBA = 0x0480128e = 75502222 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 08 88 12 80 44 00 00:01:49.355 READ FPDMA QUEUED 60 00 10 80 d5 cb 44 00 00:01:41.728 READ FPDMA QUEUED 60 00 20 60 d5 cb 44 00 00:01:41.724 READ FPDMA QUEUED 60 00 20 e0 cf 85 43 00 00:01:41.703 READ FPDMA QUEUED 60 00 08 30 0a c1 44 00 00:01:41.664 READ FPDMA QUEUED SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Interrupted (host reset) 90% 1 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.